39 resultados para flow-rate

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

SiOx films have several advantages as an interlayer dielectric in electronic devices owing to the strong adhesion between SiOx and the substrate. In this study, the coating performance as a function of the N2O flow rate was evaluated by electrochemical impedance spectroscopy and potentiodynamic polarization tests in an undisturbed environment. In addition, the coatings were examined by atomic force microscopy and Fourier transform infrared reflection spectroscopy. The SiOx films on a stainless-steel substrate showed the highest coating performance at a N2O flow rate of 120 sccm. This was attributed to the films having the lowest porosity value among those examined as a result of the fragmentation of SiO and SiO2 bonds and the improved surface roughness.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The combined effect of scan speed, hydrogen and air flow rates on the flame ionization detection (FID) peak response of phospholipid classes has been studied to determine the optimum levels of these parameters. The phospholipid composition of different types of commercial lecithins, as well as lecithins combined with fish oils, has been analyzed by Iatroscan TLC‐FID Mark‐6s under optimized conditions. An air flow rate of 2 L/min, a hydrogen flow rate of 150–160 mL/min, and a scan speed of 30 s/rod seem to be the ideal conditions for scanning phospholipids with complete pyrolysis in the flame in the Mark‐6 model. Increasing the scan speed rapidly decreased the FID response. A hydrogen flow rate as high as 170 mL/min could be used at relatively low air flow rates (&#x003C2 L/min) and the response declined when both air flow rate and hydrogen flow rate increased simultaneously. Both linear and curvilinear relationships had highly significant correlations (p&#x003C0.01) with the sample load. Time course reactions, including the hydrolysis of phosphatidylserine using enzymes, can be successfully monitored by the Iatroscan TLC‐FID Chromarod system.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A 23.5-fold purified exoinulinase with a specific activity of 413 IU/mg and covalently immobilized on Duolite A568 has been used for the development of a continuous flow immobilized enzyme reactor for the hydrolysis of inulin. In a packed bed reactor containing 72 IU of exoinulinase from Kluyveromyces marxianus YS-1, inulin solution (5%, pH 5.5) with a flow rate of 4 mL/h was completely hydrolyzed at 55 °C. The reactor was run continuously for 75 days and its experimental half-life was 72 days under the optimized operational conditions. The volumetric productivity and fructose yield of the reactor were 44.5 g reducing sugars/L/h and 53.3 g/L, respectively. The hydrolyzed product was a mixture of fructose (95.8%) and glucose (4.2%) having an average fructose/glucose ratio of 24. An attempt has also been made to substitute pure inulin with raw Asparagus racemosus inulin to determine the operational stability of the developed reactor. The system remained operational only for 11 days, where 85.9% hydrolysis of raw inulin was achieved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A fixed bed photocatalytic reactor has been designed and built with a UV
radiation source. Ti02 pellets were placed on the three fixed beds within the
reactor. Acetone was used as an indicator of volatile organic compounds (VOCs) during the experiment. Under the flow rate of 12.75 l/min, the oxidation efficiencies were obtained at four different concentrations of acetone laden gas streams ranged from 40ppm to 250ppm. It was found that the lower the acetone concentration of the untreated inlet gas, the higher the oxidation efficiency; the obtained oxidation efficiency was in the range of 40-70% for various concentrations of untreated gases.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Volatile Organic Compounds (VOCs) are air pollutants that come from burning fossil fuels and industrial emissions. They have potentially adverse health effects being carcinogenic and highly persistent in the environment. The use of photocatalytic oxidation to remove VOCs has the potential to be applied in indoor air quality improvement and industrial emission control. A fixed bed photocatalytic reactor was designed and built. UV black light lamps were installed in the reactor to provide a source of UV radiation. A non-film titania media as pellets were placed on the three fixed beds within the reactor. Toluene and acetone were used as indicators of VOCs during the experiment. With a flow rate of 12.75l/min, the oxidation efficiencies were obtained at four different concentrations of acetone laden gas streams ranging from 40ppm to 250ppm. It was found that the lower the acetone concentration of the untreated inlet gas, the higher the oxidation efficiency. The oxidation efficiency was in the range of 40–70% for various concentrations of untreated gases. Two concentrations of toluene laden gas stream were also tested using the same reactor. The oxidation efficiencies were found as 50% for 120ppm toluene gas and 45% for 300ppm toluene gas. It was found that the times required for toluene to reach oxidization equilibrium have been halved than for acetone gas stream. Other parameters such as flow rate and UV intensity were also altered to see their effects on the oxidation efficiency. A full spectrum scan was carried out using a Bio-rad Infrared spectrometer. It was found that the main components of the treated gas stream from the outlet of the reactor were CO2 and water along with small amount of untreated acetone. The suspected intermediates of aliphatic hydrocarbons and CO were found in very minimal amounts or undetectable. The research experiments supported that the TiO2 pellets can work effectively in a fixed bed photocatalytic reactor and achieve significant oxidation efficiencies for degradation of toluene and acetone as indicators of VOCs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper reports the effectiveness of the photocatalysis TiO2 in degrading Lanasol Blue CE. A flat-plate reactor (FPR) with a reactor area of 0.37 m2 and ultraviolet (UV) light source of six 36 W blacklight lamps was used in the study. Operating variables including dosage of the photocatalyst, flow rates through the FPR, UV intensity, and tilted angle of the reactor were investigated to degrade Lanasol Blue CE. Results showed that the photocatalytic process can efficiently remove the color in textile dyeing effluent. The degradation process was approximated using first-order kinetics. The photocatalytic apparent reaction rate increased with the increasing UV intensity received by the photocatalyst TiO2 in slurry. The liquid flow rate and tilted angle influenced the film thickness. The apparent reaction rate constant was mainly determined by the liquid film thickness, UV intensity, and the dosage of the photocatalyst. The findings of this research can be utilized as preliminary input for potential solar photocatalytic applications on color removal from dye solutions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Urban stormwater non-point source pollutants are recognized as a major cause of receiving waters quality deterioration. To date most research has focused on specifying temporal variations of stormwater quality parameters which includes high uncertainties and also increases the risk of pollution control structures failure. Traditionally, the temporal variations of quality parameters in forms of either pollutograph or Event Mean Concentration (EMC) is obtained by sampling stormwater at the outlet of urban catchments for quality analysis in addition to measurement of flow rate over years. Spatial variations of the runoff quality are the key factor in non-point source pollution studies. This research investigates spatial variability of urban runoff quality parameters such as Total Phosphorous (TP), Total Nitrogen (TN), Suspended Solids (SS) and Biochemical Oxygen Demands (BOD) in relation to land use of urban catchments. In spatial analysis, stormwater will be sampled over the whole catchment area for a number of rainfall events during a year without any requirement to measure flow rate. This research showed comparable results for average pollutant concentrations with those of other urban catchments in Australia where traditional sampling method was used. The research outcomes will reliably estimate pollutants concentration for improved and efficient design of pollution control structures for each land use.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With information access becoming more and more ubiquitous, there is a need for providingQoSsupport for communication that spans wired and wireless networks. For the wired side, RSVP/SBM has been widely accepted as a flow reservation scheme in IEEE 802 style LANs. Thus, it would be desirable to investigate the integration of RSVP and a flow reservation scheme in wireless LANs, as an end-to-end solution for QoS guarantee in wired-cum-wireless networks. For this purpose, we propose WRESV, a lightweight RSVPlike flow reservation and admission control scheme for IEEE 802.11 wireless LANs. Using WRESV, wired/wireless integration can be easily implemented by cross-layer interaction at the Access Point. Main components of the integration are RSVP-WRESV parameter mapping and the initiation of new reservation messages, depending on where senders/receivers are located. In addition, to support smooth roaming of mobile users among different basic service sets (BSS), we devise an efficient handoff scheme that considers both the flow rate demand and network resource availability for continuous QoS support. Furthermore, various optimizations for supporting multicast session and QoS re-negotiation are proposed for better performance improvement. Extensive simulation results showthat the proposed scheme is promising in enriching the QoS support of multimedia applications in heterogeneous wired-cum-wireless networks.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The quality of high pressure die castings is a function of many interdependent parameters. It has been observed that many defects detected in the HPDC castings can be tracked back to poor die temperature distribution in the critical areas. It has therefore been recommended that the development of a technique to directly control the critical features - making them less sensitive to thermal related parameters - be very beneficial to the HPDC industry. From the information obtained from thermal image (processing), computational fluid dynamics has been applied to design the layout of internal cooling system and assign the flow conditions such as flow rate and pressure of the cooling water. it is observed that CFD prediction provides an excellent insight into the thermal balance of the high pressure die casting.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The photocatalyst TiO2 with UV irradiation was used to degrade dyes in textile effluent in a flat-plate photoreactor. A test system was built with the reactor area of 1 x 0.3m2, UV light of six 36W-blacklight. TiO2 powder P25 with BET surface area 50±15m2/g, average primary particle size 21 nm, purity> 99.5% and content of 83.9% anatase and 16.1 % rutile was used as the photocatalyst. A number of dyes commonly present in dyeing wastewater were tested in this study. The different operating parameters, such as dosage of photocatalyst, the structure of the reactor, flow rates through the flat-plate reactor, UV radiation intensity and tilted angle of the reactor, were investigated. The results showed that the photocatalytic process could efficiently remove most of the colour contained in the dyeing wastewater. It was experimentally observed that first-order kinetics was adequate for characterising the process. The flow rate and the tilted angle had some influence on the film thickness of the fluid in the reactor and the empirical correlation between the film thickness of the fluid and these two parameters was developed. The photoreaction rate was mainly determined by the film thickness of the fluid on the reactor surface and the dosage of the photocatalyst. Optimum operating parameters of the system were found to be at the film thickness of about 1.4mm and a TiO2 dosage of 1 gIL. The higher the UV intensity, the faster the reaction rate was. The results of these experiments showed that this method has the great potential for colour removal from wastewater at commercial scale.

To overcome the common difficulty of separating the used TiO2 suspension after treatment precipitation followed with filtration was used in this study to determine the separation efficiencies. On the other hand, TiO2 in a small pillar shape was also studied for photocatalytic degradation of textile dye effluent. The pillar pellet was made in Oegussa Company, Germany ranging from 2.5 to 5.3mm long and with a diameter of 3.7mm. It was almost pure TiO2 (83.2% anatase and 16.8% rutile), with a S-content of <20 ppm and a CI content of the order of 0.1 wt. %. No further elements are present in contents above 0.05 wt.%. The TiO2 pillars were placed on the flat-plate reactor that was divided by the rectangular slots and irradiated under UV light when the treated solution went through the reactor. Four dyes and their mixtures were tested. The results showed that the photocatalytic process under this configuration efficiently remove the colour from textile dyeing effluent, and pillar shape TiO2 photocatalyst was not dissolved in water and very easy to be separated from solution, enabling it to be reused many times. The first-order kinetics was adequate for characterising the photocatalytic degradation process and the photocatalytic performance was comparable to TiO2 powder. It is believed that the TiO2 pellet would be a preferable form of photocatalyst in applications for textile effluent treatment process, and other wastewater treatment processes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An experimental rig with a flat-plate solar reactor was built to study the effectiveness of degradation using the reactive methylene blue as sensitive objective. The factors that affect the degradation performance, such as dosages of photocatalyst (Ti02), initial concentration of reactive methylene blue, flow rate through the flat-plate reactor, solar UV radiation intensity and decolourising efficiency of the solution, have been investigated. The results showed that the solar PCO process with a Flat-plate Reactor could degrade the methylene blue and decolour in methylene blue solution efficiently.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Performance of advanced fabric energy storage systems has not been reported for Australian conditions. The influence pf slab thickness and air flow rate on the annual thermal load, and maximum heating and cooling demands for a typical office module using a ventilated hollow core concrete slab system has been investigated by simulation. Performance results for Melbourne are presented and comments made on other locations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A sensitive and simple high performance liquid chromatography (HPLC) method was developed and validated for the determination of thalidomide in rat plasma. Chromatography was accomplished with a reversed-phase Hypersil C18 column. Mobile phase consisted of acetonitrile-10 mM ammonium acetate buffer (pH 5.50) (28:72, v/v), at a flow rate of 0.8 ml/min. Thalidomide was monitored by ultraviolet detector at 220 nm and it gave a linear response as a function of concentration over 0.02–50 μM. The limit of quantitation in rat plasma was 0.50 ng (0.02 μM plasma concentration) with an aliquot of 20 μl. Results from a 3-day validation study indicated that this method allows for simple and rapid quantitation of thalidomide with excellent accuracy and reliability. Using this validated assay, the effect of coadministered irinotecan (CPT-11) on the plasma pharmacokinetics of thalidomide in rats was determined. Coadministration of CPT-11 (intravenously, 60 mg/kg) increased the maximum plasma concentration (Cmax) and area under the plasma concentration–time curve (AUC0–10 h) of thalidomide by 32.29 and 11.66%, respectively, as compared to the control, but none of the effect of CPT-11 was of statistical significance (P > 0.05). Concomitant CPT-11 also caused a 10.04% decrease in plasma clearance (CL) and 14.51% decrease in volume of distribution (Vd) (P > 0.05). These results suggest that coadministered CPT-11 did not significantly alter the plasma pharmacokinetics of thalidomide in rats. Further studies are warranted to explore the pharmacokinetic and pharmacodynamic interactions between CPT-11 and thalidomide.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: We examined the validity of the 20-year-old established Asian norms for pulmonary function in a contemporary cohort of Hong Kong Chinese university students. Design and participants: Pulmonary function testing was conducted in university students (n = 805). Setting: A university campus in Hong Kong. Measurements and results: Parameters recorded included gender, age, height, weight, standard lung function variables (ie, FEV1, FVC, and peak expiratory flow rate [PEFR]), and exhaled carbon monoxide (CO) level. Subjects completed a questionnaire on pulmonary health, smoking history, and their dietary and exercise habits within 3 months of the study. Data were compared with the established norms for lung function for Chinese persons from Hong Kong. On average, subjects were taller than those reported in the original cohort, on whom the established norms are based; however, FEV1, FVC, and PEFR were lower. As predicted, the exhaled CO level was higher in smokers. Those who exercised regularly had a higher FEV1 and FVC, and reported fewer respiratory complaints. Conclusions: Our findings support the idea that lung function norms not only differ across ethnic groups, but that they may be susceptible to change over a single generation within an ethnic group living in the same geographic region. Assuming the equivalence of our testing methods and those on which established norms are based, our findings shed further insight into the dynamic nature of lung function, and have implications regarding the definition of normal pulmonary function and its variance over the short term.